Trillium Silver

Overview

  • Point and click, web browser-like operation
  • Each report page is displayed on screen
  • Color-coded arrhythmias
  • No limit to number of patient files that can be stored on disk
  • On-screen help, tutorial, and hints
  • 24 hour report

Analysis Algorithm

  • Forest Medical eidos™ Holter algorithm

Minimum System Requirements

  • Windows® XP, 7, or 10 operating system
  • 100 MB of memory
  • 200 MB of disk space
  • 1024 x 768 pixel monitor
  • 300 dpi printer
  • (2) available USB Ports

Narrative Summary

  • Total QRS Complexes
  • Total Normal Beats
  • Average, Maximum, and Minimum Heart Rate
  • Total Ventricular Ectopic Beats (VE)
  • Single VEs
  • Bigeminy
  • Couplets (VE Pairs)
  • Ventricular Runs
  • Total Supraventricular Ectopic Beats (SVE)
  • Single SVEs
  • SV Couplets (SVE Pairs)
  • Supraventricular Tachycardia (SVT)
  • Irregular Rhythm
  • Tachycardia
  • Bradycardia
  • Pauses (Asystole)
  • Longest R-R Interval
  • ST Depression / Elevation
  • Patient Events

Hourly Summary

  • Maximum, Average, and Minimum Heart Rate
  • Single VEs
  • Bigeminy
  • Couplets (VE Pairs)
  • Ventricular Runs
  • Single SVEs
  • SV Couplets (SVE Pairs)
  • Supraventricular Tachycardia (SVT)
  • Irregular Rhythm
  • Tachycardia
  • Bradycardia
  • Pauses (Asystole)
  • ST Depression / Elevation
  • Patient Events

Editing

  • Change parameter setting (Tachycardia, Bradycardia, Pause, SVE, SVT, ST, or Irregular Rhythm)
  • Delete episode(s)
  • Delete, add, relabel, move beats
  • Delete, add strip to set max / min heart rate

Downloads

Graphs

  • Heart Rate
  • Pause Length
  • Ventricular Beats
  • Ventricular Run Length
  • Supraventricular Beats
  • Supraventricular Tachycardia Length
  • ST Level (all channels)
  • Artifact Index (all channels)
  • R-R Histograms
    • Normal Beats (NN)
    • Ventricular Beats
    • Supraventricular Beats

Forms

  • Beat count and sample of up to 32 Ventricular forms
  • Change form label
  • Delete all beats in form
  • Merge one form into another
  • Move beat from one form to another
  • Overlay form on beat

Strips

  • View full-scale or mini strips (9 per page)
  • Print full-scale (25 mm/sec, 2 per page), mini strips (8, 18, or 32 per page), or Strip List
  • Full-scale strip has 30 or 60 second Context ECG
  • User label and comment
  • On-screen calipers (time interval or ST level)

Full Disclosure

  • 15, 30, or 60 seconds per line
  • Any combination of 1, 2, or 3 channels
  • Color-coded beat label and episode indications
  • Patient event indication
  • Beat count per minute
  • Relabel all beats in line

Downloads

Cover Page

  • Patient Information
  • Physician Information
  • Medications / Symptoms / Conclusions
  • Customizable fields
  • Customizable layout
  • Customizable dropdown boxes for any field
  • Customizable header and logo
  • Option to include Summary Data
  • Option to include Heart Rate Graph

File

  • Save / recall report-only (MCR) file

Edit

  • Undo most operations
  • Undo all changes
  • Copy / paste text into another app
  • Reanalyze data, excluding channels

Print

  • Print preview
  • Set page margins




Holter Software Comparison Matrix


Trillium Silver Trillium Gold Trillium Platinum Trillium Platinum Vet
Standard 24-Hour Holter Reporting
Forest Medical eidos™ Algorithm
7-Day Holter Reporting
Pacemaker Analysis
PDF Output
Superimposition
High Rate Algorithm
Q-T and P-R Interval Analysis
Beat-by-Beat Output
HRVf Analysis
Very High Rate Algorithm



Choose PC Based Holter Analysis

Trillium Silver Holter Analysis Software provides easy-to-use Windows® PC based editing and analysis of Holter monitoring data from our Trillium 7000™ Holter Recorder. Trillium Silver based Holter Monitoring Systems allow you to get started with just a single recorder for 2 or 3 channel, 24 hour, monitoring applications. They are easily and economically expandable to multiple recorders and workstations.


Enhance Patient Retention

The diagnostic quality report produced by our Trillium Silver Holter Analysis Software can be used to determine if a referral to another provider is actually required. By reducing the number of unnecessary referrals you can enhance patient retention rates and improve patient satisfaction with your service while simultaneously helping to reduce the overall cost of health care.


Discover the Value Leader in Holter

Forest Medical Holter Monitoring Systems are surprisingly affordable and provide the best long term value in Holter monitoring technology. Trillium Silver based systems can be upgraded to our Trillium Gold™ or Trillium Platinum™ Holter Analysis Software when you’re ready for more advanced analysis techniques. By choosing Forest Medical, you can be sure that you’ve made the right investment in Holter monitoring technology now and for the future.


Qualify for Maximum Reimbursement

The diagnostic procedures that can be performed with Trillium Silver based Holter Monitoring Systems qualify for maximum reimbursement (CPT Code 93230).