Capabilities Overview • 32 Bit Windowsฎ Application • Point and click, web browser-like operation • Each report page is displayed on screen • Color-coded arrhythmias • Color-coded pacer spikes • No limit to number of patient files that can be stored on disk PDF Report output • On-screen help, tutorial, and hints Analysis Algorithm • Forest Medical eidos™ Holter Algorithm • Adjustment for Atrial Fibrillation / Irregular Rhythm sensitivity Very High Heart Rate analysis capability (Sustained rates up to 320 BPM) Editing • Enter Cover Page data • Reconfigure Cover Page • Delete or add Report Strips • Delete or add individual episodes, or delete all episodes • Change individual existing beat label • Insert a beat • Artifact Category Designation • Designate Artifact from Full Disclosure • Manually Designate Paced Beats • Report data is automatically recalculated • Parameter Settings • Change Report Strip Label • Change Form Label Advanced Paced Beat Analysis / Reporting Total Number of Pacer Spikes Detected Total Number of Paced Beats Detected Percentage of Pacemaker Dependency (Paced Beats/Total Beats) Minimum, maximum and average Pacer Rates Failure to Capture Failure to Sense Over-sensing Paced Beat Graphs: Rate, Frequency, and R-R Histogram Heart Rate Variability Analysis and Reporting Frequency Domain Short Term: 256 beat, 512 beat, 5 minute and 256 second interpolated presentations Long Term: 65536 Beat Tachogram, 131072 Beat Tachogram, and 24-hour Tachogram presentations Windowing: Hamming, Hanning, Triangular Black, and Harris (or none) Customizable Power Output Table Time Domain SDNN, SDANN, SDNN Index, RMSSD, and Triangular Index calculations 1 Hour Scatter Plots R-R Histograms ASCII data output capability Superimposition • One or two beats • Variable rate scanning • One beat or one minute jog-back/jog-forward • Automatic jog-back based on user reaction time • R-R histogram or tachogram side display Q-T Interval Measurement Q-T Interval vs. Heart Rate Graph • Superimposition • Editing • Q-T Calculations: Raw, Corrected • Auto Q-T Calipers R-R Interval Measurement • Shortest and Longest R-R Interval • Time-domain Heart Rate Variability statistics On-Screen Calipers • Measure time intervals or ST level • Caliper Interval Repeat • Calipers can be saved with strip • Show Rate Measurements • Show R-R Interval Measurements Report • Memory Card Data (MCD) File Storage • Memory Card Report (MCR) File Storage • Copy / paste text into Windows clipboard • Copy / paste graphs into Windows clipboard • Customize Report Layout • One Page Report Option Cover Page • Patient Information • Medications / Symptoms • Print Logo • Physician Information • Referring Physician Information • Conclusions • Parameter Settings • ICD-9 CM Drop Down Box Narrative Summary • Total QRS Complexes • Average, Maximum, and Minimum Heart Rate • Total Ventricular Ectopic Beats (VE) • Isolated Ventricular Ectopic Beats • Bigeminy, duration • Trigeminy episodes • Couplets (VE Pairs) • Ventricular Runs, duration, longest and fastest • Idio-ventricular Rhythm (<100 BPM) • Total Supraventricular Ectopic Beats (SVE) • Isolated Supraventricular Ectopic Beats • SVE Pairs • SV Bigeminy • SV Trigeminy • Supraventricular Tachycardia (SVT), duration, longest and fastest • Irregular Rhythm, duration • Tachycardia, duration • Bradycardia, duration • Pauses (Asystole) • Longest Pause (Asystole) • ST Depression / Elevation • Patient Events • Pacemaker Analysis (Total Paced Beats, Failure to Capture, Failure to Sense) |
Hourly Summary • Customizable • Average, Maximum, and Minimum Heart Rate • Isolated Ventricular Ectopic Beats • Bigeminy • Trigeminy • Couplets (VE pairs) • Ventricular Runs • Isolated Supraventricular Ectopic Beats • SV Couplets • SVE Pairs • SV Bigeminy • SV Trigeminy • Supraventricular Tachycardia (SVT) • Tachycardia • Irregular Rhythm • Bradycardia • Pauses (Asystole) • ST Depression / Elevation • Patient Events Graphs • Heart Rate • Ventricular Ectopics • Ventricular Runs • Supraventricular Ectopics • Supraventricular Tachycardia • Artifact Index (2 or 3 channel) • ST Level (2 or 3 channel) • Normal R-R Histogram • Abnormal R-R Histogram • Pacer Rate • Pacer R-R Histogram • Q-T Graph • Pause Graph R-R Scatter Plot (per hour) Ventricular Forms • Beat Count and Sample of up to 32 Ventricular Forms • Beat Count and Sample of up to 32 Normal Forms • Reclassify Forms by Prematurity and Shape • Turn off a channel Strips • Automatic Report Strips in full-scale (25 mm/sec) or mini-scale (8.5 mm/sec) format • Automatic Report Strips 8, 18, or 32 per page • Strip List • Extract strip from any time in the monitoring period • Extract all strips for an episode type Full Disclosure • Print in 1 Hour Increments • 15, 30, or 60 seconds per line • 1 Channel Only • Any combination of 2 or 3 channels • Patient event indicated by circle • Episode Count at end of line (HR, VEs, ST, SVEs) Alternate Outputs Graphs bitmapped to clipboard • Text bitmapped to clipboard Summary Report ASCII text upload • MCR File – “report-only” file (typ. <100 KB) MIT format PDF Output Fax reports Pediatrics • Rate Parameter Settings • High Rate Algorithm • Under 20 kg Patients Electronic Medical Records Support Supported Recorders Trillium 2000 Holter Recorder Trillium 4000 Holter Recorder Trillium 5000 Holter Recorder Trillium 3000 Holter Recorder/Analyzer Minimum Computer Requirements Windows 98SE; 2000; or XP, 150 MHz PII or above, 32 MB of Memory, 100 MB of Hard Disk space, SVGA Video, (2) available USB Ports, and a 300 dpi or higher resolution printer Available Downloads • Trillium Platinum™ Holter Analysis Software Data Sheet (189 KB) • Trillium 2000™ Holter Recorder Data Sheet (90 KB) • Trillium 4000 Holter Recorder Data Sheet (PDF: 93 KB) • Trillium 5000 Holter Recorder Data Sheet (PDF: 98 KB) • Trillium 3000™ Holter Recorder/Analyzer Data Sheet (104 KB) • Summary Report (PDF: 612 KB) • Full Scale Strips (PDF: 687 KB) • Strips 8 Per Page (PDF: 919 KB) • Strips 18 Per Page (PDF: 194KB) • Strips 32 Per Page (PDF: 829 KB) • Full Disclosure 15 Seconds (PDF: 1,156 KB) • Full Disclosure 30 Seconds (PDF: 523 KB) • Full Disclosure 60 Seconds (PDF: 277 KB) • HRVf Long Term Analysis (PDF: 1,278 KB) • HRVf Short Term Analysis (PDF: 51 KB) • Time Domain Analysis (PDF: 8 KB) Sample Screens To view sample screens, please select the Screens button at left or this link which will take you to the first screen. |
||||||
![]() |
||||||||
|
|
Phone: 800-844-2037 • 315-434-9000 • Fax: 315-432-8064 |
|||||||
|
|
Home |
Site Map |
Feedback |
Information |
Search |
|||||||
|
|
Please e-mail
webmaster@forestmedical.com
with questions or comments about this web site. |
|||||||